EN 469:2005

Protective clothing for firefighters- Performance requirements for protective clothing for firefighting

 

clause

Test item

standard

requirement

Price (RMB)

6.1

Flame spread

EN ISO 15025 :2002 Procedure A

EN 533 Index 3

 

6.2*

Heat transfer -Flame

EN 367

Level 1 or 2

 

6.3*

Heat Transfer -Radiation

EN ISO 6942

Level 1 or 2

 

6.4*

Residual tensile strength of material when exposed to radiant heat

Pretreatment: EN ISO 6942

Method: ISO 13934-1

>= 450N

 

6.5

Heat resistance

ISO 17493

No ignite, melt , shrinkage <5%

 

6.6

Tensile strength

ISO 13934-1

>= 450N

 

6.7

Tearing strength

ISO 13937-2

>=25N

 

6.8

Surface wetting

EN 24920

>=4 Grade

 

6.9.

Dimensional change

ISO 5077

< +-3%

 

6.10.

Resistance to penetration by liquid chemical

EN ISO 6530

Repellency rate: < =80%

 

6.11

Resistance to water penetration

EN 20811

Level 1: < 20kPa, without moisture barrier

Level 2: >=20kPa, with a moisture barrier

 

6.12*

Water Vapour Resistance

EN 31092

Level 1: >30m2/Pa/W

Level 2: <=30m2/Pa/W

 

6.13

Ergonomic performance

Annex D

/

 

6.14*

Visibility

EN 471

Annex B

 

6.15

Optional test – whole garment testing

Annex E

/

 

One wash

 

 

Note:

1. Clause 6.1 – 6.4, 6.8-6.12, one wash or dry cleaning is needed before test.

2. All the clause marked * need to be subcontracted out.

 

如果您有任何检测方面的疑问,请随时与我们联系,我们将根据您的商品,提供最适合您的检测服务

上海统标质量技术服务有限公司

AM (Shanghai) Testing & Services Co.,Ltd

联系人:张佳慧

手机: 13381988392 (同微信)

Fax: 021-31138310

QQ: 1312003860

注:以上差异对比以新版标准报批稿为依据,仅供参考,请以各国最终发布文件为准。

相关分类

地址:中山市小榄镇民安中路163号 联系人:张总 电话:400 000 8722 微信 baxi188699386

Copyright © 市场调研|商务服务All rights reserved 京ICP备2023027404号-4 网站地图
免责声明:本站只起到信息平台作用,不为交易经过负任何责任,请双方谨慎交易,以确保您的权益。
内容的真实性、准确性和合法性由发布企业或个人负责。如有信息、图片侵权,请及时联系我们处理。
友情提醒:投资有风险 加盟需谨慎